1
The set chosen is undersized for the characteristics of the
THE SET DOES NOT
system.
SUPPLY THE
2
Excessive water consumption for the flow rate that can be
REQUIRED
supplied by the water supply source (tank, well, mains, etc.)
CHARACTERISTICS.
3
Motors turning in inverse direction.
4
One or more pumps clogged.
5
Pipes clogged.
6
Foot valves clogged or blocked (set above head).
7
Interception valves at suction and delivery partly closed.
8
Air infiltrations in the suction pipes of the set pumps.
1
The respective not return or foot valves do not close well or
WHEN STOPPED, ONE OR
are blocked.
MORE PUMPS IN THE SET
2
The respective suction pipe is not airtight.
TURN IN INVERSE
DIRECTION.
1
Motor protection fuses burnt out.
AFTER BEING
2
No current is reaching the coil of the respective remote
STOPPED, A PUMP IN
control switch.
THE SET DOES NOT
3
Remote control switch coil interrupted.
START AGAIN.
4
The system pressure is not reaching the respective control
pressure switch.
5
Faulty control pressure switch.
ENGLISH
1
Replace it with one that suits the required characteristics.
2
Increase the flow rate that can be supplied by the water
supply source.
3
Change it, performing the operation described in the
paragraph on "Starting".
4
Dismantle them and clean the pump body and the impellers,
ensuring that they are in good condition.
5
Clean them or change them.
6
Clean them or change them.
7
Open them completely.
8
Testing under pressure, check the perfect seal in the
couplings, the joins and the pipes.
1
Check seal and correct operation.
2
Check the seal, testing under pressure.
1
Change them.
2
Use a tester to check the electric circuit as far as the coil
itself and repair any interruption found.
3
Change it.
4
Remove it and clean the connecting sleeve.
5
Change it.
48