OPERATING LIMITS
COOLING
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
EG
HEATING
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
Before the installation, verify that they are fit for the unit.
UNIT
MODEL
COOLING
COOL/DRY/HEAT
POWER SUPPLY 220 / 240V ~ 50 Hz
GENERAL PRECAUTION
Check that the voltage and frequency of the power supply match those required
by the system.
Check the possibility to have the power line to the indoor unit (ELECTRIC
CABLE LENGHT 3 m).
Install a double - pole switch, protected by 10 A fuses of the delayed type,
upstream the electricity wall socket.
Verify that the power supply avaiable is sufficient for running other electri-
cal domestic appliances in use simultaneously from the same supply.
Before connecting the air conditioner to a power socket, make sure
that the socket is provied with an earth connection in compilance
with local codes.
INSTALLATION SITE SELECTION
INDOOR UNIT
AVOID:
Positioning the indoor unit into rooms where it could be sprinkled
with water (i.e. laundries).
flammable gas or large amount of mist may be expected humidity
location.
Direct sunlight or near by heat source that may affect
performance of the unit.
that obstruct air circulation.
DO:
Choose a position which allows proper ventilation in the room.
Verify respect of the minimum reccomended maintenance space.
OUTDOOR UNIT
AVOID:
Direct sunlight or area where hot air from exhaust fans investing the unit.
DO:
Choose a place as cool as possible and well ventilated.
TOOLS REQUIRED FOR INSTALLATION
Phillips head screw driver
mm wrench
24 mm wrench
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION
Anti-freeze oil for Aeroquip connections (for models with R407C use synthetic oil HAB - Alkylbenzene type ex. ZERICE S
EXXON), about 30 gr.
PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
2
OUTDOOR TEMPERATURE 46°C D.B.
ROOM TEMPERATURE
32°C D.B./23°C W.B.
OUTDOOR TEMPERATURE 19°C D.B.
ROOM TEMPERATURE
19°C D.B./14°C W.B.
OUTDOOR TEMPERATURE 24°C D.B./18°C W.B.
ROOM TEMPERATURE
27°C D.B.
OUTDOOR TEMPERATURE -8°C D.B./-9°C W.B.
NARROW TUBE
OUTSIDE DIA.
OUTSIDE DIA.
6,35 mm
6,35 mm
Separately insulated
To install in areas where leakage of
Installing unit behind curtains or forniture
(NOT SUPPLIED)
Tape measure
Level
Hammer
Hachsaw
LATGE TUBE
7,93 mm
9,52 mm
Hammer drill
Hole saw or key hole saw ø 50
Core bits 10 mm diameter drill bit.
DECLARATION OF CONFORMITY
This product is marked
as it satisfies Directives.
- Low voltage no. 73/23/CEE and 93/68/CEE.
- Electromagnetic compatibily no. 89/336/CEE,
92/31/CEE and 93/68/CEE.
This declaration will become void in case of misusage
and/or non observance though partial of Manufacturer's
installation and/or operating instructions.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE
REMOTE CONTROL
UNIT
AAA ALKALINE
BATTERY
RAWL PLUG
TAPPING
SCREW 4x30
PLASTIC PLUG
(
MALE AND FEMALE
EXPANSION
BOLT
NUT AND WASHER
OUTDOOR UNIT
BASKET OR
SUPPORT
TAPPING SCREW
FOR REM. CONTR.
CONNECTION EXTENSION
KITS - LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
PARTI
FIGURA
EXTENSION KIT
FOR CONNECTION
TUBE
CONNECTIONS
PLASTIC BOX
RAWL PLUG
TAPPING SCREW
ø 3,5 x 45
CLAMP
*
For heat pump version.
19 mm wrench
(NOT SUPPLIED)
(TO BE CONTINUED AT PAGE 3)
NR°
1
2
2
2
2 + 2
)
2
2 + 2
1
1
N°
1
1
3
3
*
2 + 8
21