Refer to local regulations in the country of use for anything
that is not speci cally covered in this manual. In Italy, refer
to standard UNI 0683 in addition to any Regional or
Local Health Authority regulations.
If the insert is to be installed in a block of apartments, con
sult the block administration before installing.
CHECKING COMPATIBILITY
CES
The insert must NOT be installed in the same room as type B
gas appliances, e tractors, etc.
See chap. 4.1 of standard NI 1 8 .
CHECKING ELECTRICAL CONNECTION
INPELLET 49 is supplied with an electrical power lead to be
connected up to a
thermal magnetic switch.
hanges in voltage by more than 1 % can affect the insert.
The electrical system must be certi ed as legally compliant.
Speci cally chec the ef ciency of the earth circuit. The power
line must be of a section that is appropriate to the insert power.
n inadequate earthing system can cause anomalies for which
Edil amin cannot be held liable.
SAFETY DISTANCE FOR FIRE PREVENTION AND
POSITIONING
To function correctly, INPELLET 49 must be positioned on the
level.
hec that the oor load capacity is suf cient.
INPELLET 49 must be installed in compliance with the fol-
lowing safety conditions:
- leave a minimum of 4 cm space to the sides and bac from
any medium- ammable materials
- leave a minimum of 8 cm space to the front from any
medium- ammable materials
If it is impossible to leave the distances given above, technical
and construction provisions must be ta en to avoid all re ris .
If connected to a wooden wall, or wall constructed from ano-
ther ammable material, the smo e e haust pipe and other hot
parts must be insulated with ceramic bre or other, similar ma-
terials, to prevent heat transmission and resulting re hazards.
AIR INTAKE
n air inta e must be prepared behind the insert and connected
with the outside. It must have a useful minimum section of
8 cm to guarantee suf cient air to the insert for combustion,
without creating depression in the installation room.
cm diameter outlet is found on the rear of the INPELLET
49.
This outlet is used for air inta e connected directly with the
outside via pipes.
The pipes must not be longer than 1 metre and have no bends
and must have a wind guard at the end.
Note:
Even in the case of direct connection, an air inlet which
connects the installation room with the outside must be set.
INSTALLATION
ITH OTHER DEVI
z soc et and preferably with a
SMOKE DISCHARGE
The discharge system must only be used for the insert (no
discharge permitted into a chimney ue shared with other
hearths).
Smo e discharge ta es place from the mouth on the cover,
measuring 8 cm in diameter.
The smo e discharge must be connected with the outside, using
suitable sealed steel pipes.
The material used to seal and if necessary insulate the pipes,
must be resistant to high temperatures (high temperature silico-
ne or mastic).
The only horizontal section allowed may be up to 1 meter long,
avoiding any counter-slopes.
p to two curves can be used with a ma . angles of no less
than 9
(see the diagrams below).
If the discharge is not into a chimney ue, an e ternal vertical
stretch will be required of at least 1. metres, and a
windproof terminal (reference chap. 4.
This e haust pipe must nevertheless surpass the height of the
eaves of the roof.
If the discharge is into a chimney ue, this must be suitable
for solid fuels. If it is more than 1
re-established by threading it with a new ue. The resulting
hollow space between the new and old ue must be sealed with
insulating material.
A: internal chimney ue up to the roof
B: e ternal bric -built chimney ue
C: internal bric -built chimney ue
D: double-wall e ternal steel chimney
ue (for the following installation, the
**
chimney ue must be double-walled and
well-insulated for the entire length)
**
respect to horizontal
CHIMNEY POT
The main characteristics are:
- an internal cross-section at the base, which is the same as that
of the chimney ue
- an outlet cross-section which is no smaller than twice that of
the chimney ue
- its position must be high enough to catch the wind and avoid
downdraft areas in turbulent wind..
- 27
-
NI 1 8 ).
mm diameter, it must be
**
**
ma incline of no less than 4
**
with