Model S19-2000 Series
Installation Instructions: Valve with Optional Recess-Mounted Cabinet
Note: Flush the supply lines before beginning installation.
1. Rough in a 11-1/2" W x 13" H hole in the wall for the cabinet (see Figure 3).
2. Measure and mark the cabinet mounting hole locations at the dimensions shown in Figure 3. Install four
1/4" wall anchors, if required (supplied by installer).
3. Insert the cabinet into the wall opening and secure into place with four 1/4" wall fasteners (supplied by
installer).
4. Insert the valve into the bracket in the cabinet (right side of the valve goes in first). Install the valve,
elbows and stops onto the inlet and outlet piping.
5. Continue with the valve installation procedure found on page 3.
FRONT VIEW
5-3/8"
(137)
11-1/4"
(286)
Door
3"
(76)
(330)
Figure 3
4
9-3/4"
(248)
Door
Flange
14-1/2"
(368)
5"
(127)
11"
(279)
Box
13"
BOTTOM VIEW
11"
11"
(279)
(270)
5/14/08
Installation and Maintenance Instructions
2-1/2"
1/2" NPT Outlet
(64)
7-1/2"
(190)
9/32" (6) Ø Holes
(4) Each Side
(8) Total
Bradley Corporation • 215-1291 Rev. L; EN 07-903A
SIDE VIEW
2"
(51)
2"
(51)
2-1/2"
(64)
12-1/2"
(318)
2-1/4"
(57)
6-1/2"
(165)
1/2" NPT Inlets