X3/
Signal
type
62
Analog
output
7
−
8
Analog
input
9
−
20
−
28
3)
E1
3)
E2
Digital
inputs
E3
E4
39
−
A1
Digital
output
59
−
1)
Output level 0
+10 V: Adapt offset (C0109/C0422) and gain (C0108/C0420)
2)
Adjust offset (C0026) and gain (C0027) separately for each function module ...
− after replacing the function module or the basic device.
− after loading the Lenze setting.
3)
Frequency input alternatively 0
10 kHz single−track or 0 ... 1 kHz two−track, config. via C0425
EDK82ZAFSC−100 DE/EN/FR 4.0
Function
(Lenze setting: bold print)
Output frequency
GND1,
Reference potential for analog signals
Input for actual value or setpoint
Switch over the range with the DIP switch and in C0034:
l
Voltage signal
l
Current signal
Internal, stabilised DC voltage source for the
setpoint potentiometer
Internal DC voltage supply for control of digital
inputs and outputs
Controller inhibit (CINH)
Activation of JOG frequencies
JOG1 = 20 Hz
JOG2 = 30 Hz
JOG3 = 40 Hz
DC−injection brake (DCB)
Change of direction of rotation
CW/CCW rotation
GND2,
Reference potential for digital signals
Ready for operation
l
internal supply:
l
external supply:
DC supply for X3/A1
l
internal (bridge to X3/20):
l
external:
Electrical installation
l
Wiring
Level
(Lenze setting: bold print)
0
+6 V
0
+10 V
1)
−
0
+5 V
0
+10 V
−10
+10 V
2)
0
+20 mA
+4
+20 mA
+4
+20 mA (open−circuit
monitored)
+5.2 V
+20 V ±10 % (ref.: X3/7)
1 = enable
e1
JOG1
1
JOG2
0
JOG3
1
1 = DCB
E4
CW
0
CCW
1
−
0
+20 V
0
+24 V
+20 V
+24 V
6
E2
0
1
1
41