The displayer will show alternatively 7,0 and – flashing during the calibration (1 to 5 minutes).
7.0
- -
If the measured value is correct, the device shows « oh » and then displays the value 10.
Rinse the pH probe in the water and drain it without drying it with a rag.
Insert the pH probe in the pH 10 solution, wait for 1 minute and then valid by
The displayer will show alternatively 10 and
10
- -
If the measured value is right, the device shows « Oh » and then fall over towards the current display of the
pH.
Note : the probe being in the pH 10, the device flashes 10, because it measures a high pH. The pH high alarm will
disappear from the real measure of the swimming pool.
If one of the values is incorrect, the device shows « Er ». Your pH probe is probably no more usable (lifespan),
to proceed to its replacement, contact your professional.
Remove the cork and then put back the probe on the probe holder.
7/ DIAGNOSTIC OF THE FAILURES
1

SECURITIES

2
Securities
The device has detected an abnormal value of the pH, either too high (example: 8.2) or
too low (example: 6.0).
The regulation is interrupted.
pH value
1/ Control the pH value directly in the pool with your usual analysis kit.
flashing
2/ In case of abnormal pH, stop the device. Add the pH acid corrector (pH too high) or pH
basic (pH too low) directly in the pool to the buzzards of expulsion. Wait for 30 minutes.
Restart the device up.
In case of normal pH, calibrate the pH probe (see § 6.2).
The device has detected that the last pH correction attempts are unsuccessful.
The REGULATION is interrupted.
1/ Check that the pH corrective tin is not empty.
« AL »
2/ Measure by hand the value of the pH in the pool with your usual analysis kit and
message
compared it with the value indicated by the device :
flashing
POMPE DOSEUSE AQUALUX pH – PAPI004045AQUALU – FR/EN/IT/DE – Rev.03.15
7.0
10
If the value is different, calibrate the probe (see § 6.2)
If the value is similar, contact your professional.
- -
flashing
during the calibration
Causes / Remedies
.
V
(1 to 5 minutes).