AQUALUX I0545I Notice D'installation Et D'entretien page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
ACCESSORIES
Put the first saddle at the middle of the horizontal pipe of a minimal length of 40 cm. Direct the opening
upward. Mark then drills the pipe. Assemble with some Teflon the probe-holder on the saddle.
Remove the protection rubber of the ph probe and then assemble on probe-holder (watch whatever it is
not in abutment with the pipe).
Connect the cable of the pH probe (BNC jack) on the base of the controller box. Take it away from quite
different electric cable to avoid electromagnetic disturbances which can falsify the measures.
Position the second saddle after the first one. Direct the opening rather upward. Mark then drills the
pipe. Assemble with some Teflon the injection connexion ½ '' on the saddle. The injection connector has
to be closed to the expulsion towards the swimming pool.
Connect the exit of the pH pump of the injection connector with the rest of the supplied pipe.
3
PH PROBE AND INJECTION SYSTEM
1/ Connect the suction strainer to the entry of the pH pump with a
part of the supplied pipe. Respect the sense of arrows representing
on the top of the pH pump.
2/ Install with some Teflon and hand screw the injection connector
on the second saddle. Connect the exit of the Ph pump to the
injection connector with the rest of the supplied pipe (respect the
sense of arrows).
3/ Install with some Teflon the probe-holder on the first saddle,
connect it with the measure chamber kit. Remove the rubber
protection at the end of the pH probe. Push the probe in the probe-
holder (make sure that it is not in abutment with the waterworks).
4/ Connect the cable of the pH probe (BNC jack) under the controller
box.
Note: The probe must be installed vertically on the saddle. A different assembly will damage the precision of the probe
measure (can make it non efficiency).
1/
POMPE DOSEUSE AQUALUX pH – PAPI004045AQUALU – FR/EN/IT/DE – Rev.03.15
4/
NON
3/
2/
An incorrect positioning of
the injection connector can
entail the deterioration of
the pump.
5