6/ Maintenance; Calibration Of The Ph Probe - AQUALUX I0545I Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a pH production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors
may cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.

6/ MAINTENANCE

1
WINTERIZING
In case of pool winterizing (draining and/or stop of the filtration), achieve the following operations :
Remove the pH probe of the pipe.
Keep it in his original protection filled with city water (or in a glass), in a place where it will not freeze
during winter.
Rinse the flexible pipe of the peristaltic pump with clean water. Put a tin of water in the place of the pH
corrective agent tin and use the function "MA" of the pH control menu (see § 4.2).
2

CALIBRATION OF THE pH PROBE

2
The pH probe is submitted to the referential curve which moves in the time, depending on the using of the
pool. For an optimal regulation, it is important to proceed to a calibration each starting of the swimming pool
or changing of the probe.
Before proceeding to a calibration, provide you of pH7 and pH10
Reach the setting menu and then press 3 s on the key
Select the « CA » code using the keys
The screen flashes « 7,0 », the first calibration point.
CA
7.0
Dip the pH probe in the pH 7 solution, wait for 1 minute and valid by
(1)
ref. pH probe: PDEPH
(2)
ref. pH7 solution: PDSTPH7 / ref. pH10 solution: PDSTPH10
POMPE DOSEUSE AQUALUX pH – PAPI004045AQUALU – FR/EN/IT/DE – Rev.03.15
(1)
V
and valid by
(2)
standard solutions.
.
.