SMALL
HOLES
GOOD
A
GOOD
C
AGUJEROS
EN BUEN
PEQUEÑOS
ESTADO
A
EN BUEN
ESTADO
C
PETITS TROUS
CORRECT
A
CORRECT
C
Figure 10
Page 28
MAINTENANCE (CONT)
Maintenance Of The Motor
This machine has a vacuum motor that uses carbon
brushes. The carbon brushes in the motor must be
checked every three months, or every 500 hours of
operation, whichever comes first. If either of the brushes
is shorter than 3/8 inch, replace both of the carbon
brushes.
UNEVEN
How To Check The Commutator And The Carbon
GOOD
Brushes
B
HIGH MICA
To check the commutator and the carbon brushes follow
this procedure:
IRREGULAR
EN BUEN
ESTADO
B
MICA ALTA
10. Remove the carbon brush assemblies.
11. Check the carbon brush assembly. Replace both
INÉGAL
12. Put the motor brushes in position.
CORRECT
13. Using the two screws, install the bracket that holds
B
MICA ÉLEVÉ
14. Install the plastic motor cover.
15. Connect the ground wire.
16. Install the motor holding bracket.
17. Install the lower housing to the upper housing.
CLARKE TECHNOLOGY
WARNING:
Electrical inspections must be made
by a person authorized to make
electrical repairs.
1. Disconnect the power cord from the electrical outlet.
2. Empty both tanks.
3. Unlatch tanks from lower housing.
4. Lift the upper housing from the lower housing.
5. Disconnect the ground wire.
6. Remove the plastic motor cover.
7. Inspect the commutator. See figure 10. Take the
machine to a Clarke Technology authorized repair
location if you see any of the following conditions:
a. Small holes in the surface of the commutator.
See "A" in figure 11.
b. Uneven color. Look for an even dark brown
color. Clean areas or very dark areas indicate a
problem.
See "B" in figure 11.
c. High mica. The mica insulation must be lower
than the commutator bars. See "C" in figure 11.
8. To check the carbon brush assemblies, remove the
two screws from the holding bracket.
9. Remove the brackets.
carbon brush assemblies if either carbon brush is
shorter than
3
/
inch. If either brush is shorter than ½
8
inch, order replacement brushes. Be ready to
replace both carbon brushes earlier than the
normal inspection time.
the carbon brushes.
B
®
EXT
-100, 100H, 300HV 230V Operator's Manual