OBJ_BUCH-1527-001.book Page 12 Thursday, December 22, 2011 11:16 AM
12 | English
Power supply unit
Output (direct current)
– Output voltage
– Output current
Storage temperature
Operating temperature
Relative humidity
Weight according to EPTA-Procedure 01/2003
Protection class
Assembly
Operating and Storage Environment
The measuring tool is suitable exclusively for commercial op-
eration in enclosed locations.
It can be firmly mounted or placed on a flat, non-flammable
work surface.
For proper operation, please observe the information on op-
erating temperature and humidity (see "Technical Data",
page 11).
Connecting the Screwdriver (see figure A)
Use only original cables! Before each use, check the
power tool, cables and plugs for possible damage. Ca-
bles may not be repaired, but must be exchanged.
Always connect the power tool to the PUC-EXACT power sup-
ply unit first, before connecting the power supply unit to the
power supply.
– Insert tool cord 7 into connection socket 1 of the PUC-EX-
ACT power supply unit. Pay attention that the groove 8 in
the coupling of the tool cable fits onto the cog in the con-
nection socket. Screw sleeve 6 clockwise onto the connec-
tion socket.
Disconnecting the Screwdriver from the Power Supply
Unit
– Screw the socket sleeve 6 in anticlockwise direction from
the connection socket 1 of the power supply unit, and pull
the tool cord 7 from the connection socket.
Connection to the Power Supply (see figure B)
Observe the mains voltage! The voltage of the power
source must correspond with the data on the type plate of
the power supply unit.
For connection of the power supply unit to the power supply,
use only mains cables suitable for your power source. If re-
quired, exchange the supplied standard mains cable for sock-
et outlets with the earthing contact against a mains cable suit-
able for your power source.
For corded straight screwdrivers with lever start, pay at-
tention not to place the screwdriver down on the lever before
1 619 929 K08 | (22.12.11)
PUC-EXACT-1
V
36
A
11
°C
–20 to +70
°F
–4 to +158
°C
–5 to +50
°F
+23 to +122
20– 95, free of moisture con-
%
densation
kg
2.6
lbs
5.7
/I
having connected the PUC-EXACT power supply unit to the
power supply. This prevents accidental starting of the screw-
driver.
For corded straight screwdrivers with push start, pay at-
tention not to apply axial pressure to the screwdriver when
connecting the PUC-EXACT power supply unit to the power
supply. This prevents accidental starting of the screwdriver.
– Firstly, insert the connection plug 9 of the power cord 5 in-
to the connection socket 10 of the PUC-EXACT power sup-
ply unit. The PUC-EXACT can now be connected to the
power supply by inserting the power plug 11 into a ground-
ing-type outlet.
Always connect the power cord with the PUC-EXACT power
supply unit first before inserting the power plug 11 into the
outlet, otherwise there is danger of an electric shock.
Disconnecting from the Power Supply
– Firstly, pull the power plug 11 from the socket outlet. Then
pull the connection plug 9 of the power cord out of connec-
tion socket 10 of the power supply unit.
Always disconnect the connection to the socket outlet first, in
order to prevent electric shock.
Operation
Starting Operation
Switching the PUC-EXACT Power Supply Unit On/Off
(see figure C)
The PUC-EXACT power supply unit must be put into operation
first before you can switch on the C-EXACT power tool (see
"Anschluss an die Energieversorgung", page 12).
– To switch on the power supply unit, press the On/Off
switch 2 on the power supply unit to position 1.
The green lit LED indicator 3 indicates when the power
supply unit is ready for operation.
PUC-EXACT-1: When LED indicator 4 lights up, a malfunc-
tion is given.
– To switch off the power supply unit, press the On/Off
switch 2 on the power supply unit to position 0.
PUC-EXACT-3
36
6.7
–20 to +70
–4 to +158
–5 to +50
+23 to +122
20– 95, free of moisture con-
densation
2.6
5.7
/I
Bosch Power Tools