INSTALLATION
INSTALLATION
4.2.2 Wall mounting
A
Hanging notches
The condensate collecting vessel has hanging notches so that the
appliance can be hung on screws on the wall. Use appropriate
fixing materials.
»
Drill two holes 262 mm apart from one another.
»
Insert a screw into each hole.
»
Hang the appliance from the screws.
4.3

Hydraulic connection

4.3.1 Connecting the condensate inlet
The condensate inlet can be fed through any one of the four round
openings in the lid of the condensate collecting vessel.
12 |
1
2
3
1
Condensate drain from the main appliance
(heat pump for example)
2
Hose clamp
3
Pipe bend
»
Snap the cover off the required opening.
»
Insert the condensate inlet into the opening. As a reducer
between the condensate inlet and the collecting vessel, we
recommend using a soldered Cu elbow (22 mm diameter, part no.
5002 A (two fem. connections) or 5001 A (one fem. connection)).
Connect the elbow to the inlet hose using a hose clamp.
Ensure that the condensate inlet has an even gradient of at least
1% until the point at which it enters into the collecting vessel.
4.3.2 Connecting the condensate drain
The condensate drains off via the check valve which is built into
the appliance.
2
1
1
Non-return valve
2
Drain hose
»
Connect the supplied drain hose to the check valve. If necessary,
warm up the hose beforehand in warm water.
»
Direct the drain hose to an available drain. The drain hose should
be laid in such a way that it initially points upwards and then
down at a slight angle to the drain.