Operating the Refrigerator Controls: (All N7V and N8V models)
Ignition and start up:
Control boards are extremely sensitive. Evidence of tampering or removal from protective case
NOTICE
will VOID any warranty.
Before ignition or start up of the refrigerator:
- Make sure the air flow in the lower intake vent , through the refrigerator coils and condenser, and out the upper
exhaust vent is not blocked or decreased.
- Make sure there are no combustible materials in or around the refrigerator.
- Make sure the DC voltage to the refrigerator is 12.0VDC.
Air in the propane gas supply lines
For safety reasons,the refrigerators electronic controls are designed such that while operating in the LP
NOTICE
GAS mode, the trial for ignition (maximum amount of the time the gas valve and igniter can be left on
without a flame present) is limitied to 30 seconds. When starting the refrigerator for the first time, after
storage, or after replacing the propane gas tank, the propane gas supply lines can have air in them.
Due to air in the gas supply lines, the burner may not ignite within the 30 second time limit. In the event
this should happen the gas valve and igniter outputs will be turned off, the LP Gas mode will be "locked
out", and the appropiate fault code will be shown in the display. See fault code section of this manual.
The gas lock out condition can be reset by powering the refrigerator OFF and then back ON, at which time,
a new 30 second trial for ignition will commence. It may be necessary to repeat this procedure several
times before expelling all the air from the LP gas supply line. If after repeated attempts, a flame is not
established, stop and consult your local dealer
or Authorized Norcold Service Center.

Automatic mode operation (N7V and N8V Models)

- Touch and release the ON / OFF button [30] to turn the
refrigerator on.(See Art02628)
- If the indicator light [185] glows solid green, it means:
- 120 volt AC power is available to the refrigerator.
- The refrigerator is operating on AC electric power.
- If the indicator light [185] glows solid amber, it means:
- 120 volt AC power is not available to the refrigerator.
- The refrigerator is operating on propane gas.
- If the indicator light [185] glows solid red, it means:
- There is a problem and the refrigerator is not cooling.
- Refer to the "Fault code" section of this manual.

Shut down:

- To shut down the refrigerator, touch and hold the ON/OFF button [30] for two seconds and release.

Backup operating system:

This refrigerator has a backup operating system. The backup operating system allows the refrigerator to continue to cool if the
temperature sensor of the refrigerator should fail. If this failure occurs:
- The refrigerator automatically changes to the backup operating system.
- The indicator light [185] will turn off for one second, every twenty seconds.