1
Inserting battery
Open the battery compartment
and insert battery according
to the symbols. Be sure to pay
attention to polarity.
2
Switching on and measuring
!
Make sure that the reference function is deactivated before measuring
(no REF in the display).
– Switch the DigiLevel Plus on using the on/off switch (3).
– The slope angle (8) is shown in the display. If slopes are
measured overhead, the direction of display adjusts automatically.
3
Calibration
1. Place the measuring face (4) on an even surface
with position mark. Switch on device (3).
To access calibration mode simultaneously press
buttons 1 and 3. -1- appears on the display.
2. Press the ON/OFF button (3) again.
-1- flashes. The display then changes to -2-.
3. Turn the spirit level by 180° and place it exactly
on the marked surface. Now press the ON/OFF
button (3). -2- flashes. Calibration is concluded
when the measured value appears on the display.
MasterLevel Compact Plus
+
11
EN