40 reverting to factory settings
Attention! Before connecting or disconnecting any supplementary modules, receivers,
counters or jumpers, switch off the power supply and pull out the plug!
Instant stop - input potential-free = 8
Instant stop - output potential-free = 7
Light barrier jumper = 6
Light barrier jumper 0 V earth = 5
24 V DC unstable / 80 mA = 4
24 V DC unstable / 80 mA = 3
Start/stop 0 V earth = 2
Start/stop push-button potential-free = 1
2-wire light barrier
1
2
3
4
5
Attention:
Any mistakes pressing the buttons can only be deleted by switching off
and pulling out the 230 V plug.
Subject to technical modifications without prior notice.
Connection receiver (Molex 10 pol.)
Press TL 5 sec. until yellow LED lights permanently.
Press TL 5 sec. until red LED lights permanently.
Press TL 5 sec. again until yellow LED begins to flash.
Now press TL 3 times briefly until red and yellow LEDs begins to flash.
Press TS and maintain pressed until red and yellow LEDs begins
to flash and green LED lights permanently.
Press TL briefly until red and yellow LEDs turns off.
The green LED will stay lit as long as TL is pressed. Confirm factory setting.
Green light
max. 230 Vac - 120 W
Warning lamp - Red light
max. 230 Vac - 120 W
TF = Radio signal button
DIP-Switch see above
LED1 learn red
TL = pushputton learn
LED2 force yellow
TS = pushputton start
LED3 start green
TP-40. 1 -07/13