Attention! Before connecting or disconnecting any supplementary modules, receivers,
counters or jumpers, switch off the power supply and pull out the plug!
9 8
7 6 5 4 3 2
-
2-wire light barrier
Instant stop - input potential-free = 8
Instant stop - output potential-free = 7
Light barrier jumper = 6
Light barrier jumper 0 V earth = 5
24 V DC unstable / 80 mA = 4
24 V DC unstable / 80 mA = 3
Start/stop 0 V earth = 2
Start/stop push-button potential-free = 1
2-wire light barrier
Message
Control unit ready after being switched on (mains switch)
If there is an integrated radio receiver
Menu item "Learn travel path and power" is displayed
Menu item "Learn travel path and power" activated
In the process of learning travel path and power
Force cut off due to obstacle hit during movement
Start button OR 1st channel of hand-held transmitter activated Off
2nd channel of hand-held transmitter for
day light/partial opening
Interruption caused by emergency stop
Interruption caused by light barrier
Error Messages
Learning travel path and power not ok
(emergency light blinks 10 times)
Error message related to the security feeds
including emergency stop
Autotest light barrier
Autotest safety distance
EEPROM data missing
EEPROM damaged
Relays damaged
Drive motor damaged
Electric circuit faulty
Attention!
Error messages on the display can be erased only by switching off and turning back on the power supply
(pulling the mains plug).
Subject to technical modifications without prior notice.
1
+
Messages by LEDs
LED 1 red (TL)
LED 1 red (TL) LED 2 yellow Recommended
4 x Blinking
Permanent light
Permanent light
Permanent light
4 x Blinking
Blinking
Blinking
2 x Blinking
2 x Blinking
Function DIP- Switch
N°1- OFF Automatic closure off
N°1- ON Automatic closure on
N°2- OFF Short partial opening
N°2- ON Complete partial opening
N°3- OFF Light barrier off
N°3- ON Light barrier on
Connection receiver (Molex 10 pol.)
LED 2 yellow
Off
Off
Off
Off
Off
On
Off
blinking
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
Off
Repeat process
Off
Check on the security feeds
Blinking
Only deadman operations possible until repaired
Permanent light
Only deadman operations possible until repaired
Off
Repeat travel path and power learning process
On
PCB blocked, Briefly disconnect mains plug
Blinking
PCB blocked, Briefly disconnect mains plug
Off
Contact customer service
On
Only deadman operations possible until repaired
programming 29
RL
max. 230 V AC
max. 120 W
Green light
max. 230 Vac - 120 W
Warning lamp - Red light
max. 230 Vac - 120 W
TF = Radio signal button
DIP-Switch see above
LED1 learn red
TL = pushputton learn
LED2 force yellow
TS = pushputton start
LED3 start green
LED 3 green
LED 4 red (TF)
Off
10 x blinking
Off
blinking
Off
Off/blinking
Off
Off/blinking
Briefly activated
Off/blinking
Off
Off/blinking
On
Off/blinking
Off
On
Off
Off/blinking
Off
Off/blinking
GL
TP-40. 1 -07/13