Atention! before connecting or disconnecting any suplementary modules,
receivers, counters or jumpers, it's absolutely necessary to cut the power
supply (pull off the plug)!
9 8
7 6 5 4 3 2
-
8,2 kOhm +/- 5%
2-wire light barrier
Instant stop - input potential-free = 8
Instant stop - output potential-free = 7
Light barrier jumper = 6
Light barrier jumper 0 V earth = 5
24 V DC unstable / 80 mA = 4
24 V DC unstable / 80 mA = 3
Start/stop 0 V earth = 2
Start/stop push-button potential-free = 1
2-wire light barrier
The control board has circuit points for Green light and Red light/ Warning lamp. Following table
shows us when which lamp lights or flashes.
Door condition
Door open position
Door closed position
Door stops in
middle position
Advance warning
before opening
Clearing-time
Door moving
Advance warning
before warn function
Automatic closure
Automatic closure can be activated with DIP1= ON. Attention: If automatic closure function
is working it is impossible to close the door in warn function-time. If the door hits an object
or if the light barrier reacts the door will open. But if the automatic closure is on and the door
hits an object then it will hit that object 3 times and after that the door opens completely.
We need to erase that function problem to continue working with the door.
Subject to technical modifications without prior notice.
1
+
Warning lamp and traffic light function
Green light
on
off
off
off
off
off
off
Connection and function of Warning lamp and traffic light 35
Function DIP- Switch
N°1- OFF Automatic closure off
N°1- ON Automatic closure on
N°2- OFF Short partial opening
N°2- ON Complete partial opening
N°3- OFF Light barrier off
N°3- ON Light barrier on
Connection receiver (Molex 10 pol.)
Warning lamp, Red light
off
off
advance warning
before opening
off
flashing
flash
flash
flash
RL
GL
max. 230 V AC
max. 120 W
Green light
max. 230 Vac - 120 W
Warning lamp - Red light
max. 230 Vac - 120 W
TF = Radio signal button
DIP-Switch see above
LED1 learn red
TL = pushputton learn
LED2 force yellow
TS = pushputton start
LED3 start green
on
TP-40. 1 -07/13