Always isolate the heater from the mains supply when adjusting the angular
position.
Disconnect from the mains before commencing
any maintenance procedure including cleaning.
To ensure optimum heat effectiveness, it is recom-
mended that after the heater has been used for
approximately 80-100 hours, that the guard and
lamp are removed and the reflector is wiped with
a lint-free cloth before reassembling.
If the supply cord becomes damaged, it must be
replaced by the manufacturer, its service agent or a qualified person.

REPLACING THE LAMP

1.
Disconnect the power supply and ensure
that the lamp is cool.
2.
Remove the two self-tapping screws from
the side cover of the casing. (See Fig A)
3.
Take the side cover, front panels and grill
off. (See Fig B)
4.
Disconnect the lamp leads on both sides.
(See Fig C)
Depress the clip at one end of the lamp
and lever that end out. Repeat at other
end of the lamp.
5.
Slide the lamp outwards. (See Fig D)
Do not handle the halogen lamp with
bare hands. If it is inadvertently touched,
remove finger marks with a soft cloth and
methylated spirit or alcohol, otherwise the
marks will burn into the quartz, causing
premature heater failure.
6.
Refit in reverse order.
Power output/input
Voltage
IP Rating
Weight
Radiation range (•)
(•) for reference only
Fig E
QLIMA PEW 3015
1500W
220-240V, 50Hz
IPx5
2.5 kg
~3.2 m.
Fig 4
Fig A
Fig B
Fig C
Fig D
QLIMA PEW 3020
2000W
220-240V, 50Hz
IPx5
3 kg
~4 m.
4