III- Operation
3.1 Local time display
The parameter setting of the local time display, synchronised via NTP, is performed on the
Parameters page of the unit web server (page 10):
- HH:MM / HH:MM:ss / None (default: HH:MM).
In the HH:MM:ss mode the display is in the 24h format only.
3.2 White LED flash
A white flash can be activated while a melody is being played (scheduled bells or alerts) and/or
a text message is being displayed.
The flash luminous intensity is ajustable on 4 levels: 25%, 50%, 75% and 100%.
The flash can be deactivated from the Sigma software.
3.3 Display of a message
A text message can be added to a melody number in the utilisation screen of the Sigma software.
The message is stored in the Harmonys Trio.
When the melody number is executed, the text message is displayed while the melody is played
for at least 10s.
It is possible to displayed a message can be displayed even without any associated melody.
The text messages are limited to 50 characters. If the text fits in the screen it will be fixed, if not
the texte message will be scrolling at least twice.
When no message is specified the time is displayed unless the time display is deactivated then
nothing is displayed.
3.5 Locating the Harmonys Trio
During the « localisation » from the Sigma software, the Harmonys Trio plays a melody, displays
the product name (by default: BODET + adresse MAC, ex.:BODET-30AEA4C5BA80) and flashes.
3.6 Test
When pressing the « Test » button, the Harmonys Trio :
- plays the same melody as the regular Melodys,
- displays:
• the product name (the factory setting being « Bodet + adresse MAC »),
• a full rectangle (all LEDs ON),
• the firmware version,
- flashes.
3.7 PoE+ power supply
The Harmonys Trio must be powered in PoE +. Nonetheless Harmonys Trio will work when
powered by PoE but in this case «
the display luminous intensity as well as the flash luminosity will be restricted.
#!PoE!#
» will be displayed at start up and the volume level,
7