Product code
General specifications
Output voltage
Output waveform
Nom. battery voltage
Cont. power at 40 °C, cos phi 1
Peak load
AC connection
Efficiency (Max)
Display/read-out
Dimensions, hxwxd
Weight
Approvals
Technical specifications
Technology
Low battery voltage, switches off at
Low battery voltage, switches on at
High battery voltage, switches off at
High battery voltage, switches on at
Input current (nominal load)
No-load power consumption (ON
mode)
No-load power consumption
(Energy Saving mode)
Min. DC fuse (slow blow)
Min. cable size
Harmonic distortion typical
Cos phi
Temperature range (ambient
temp.)
Cooling
Protection degree
Protections
Options
Remote control
AC Master 12/700-120
28015700
100/110/115/120 Vac (± 3%) –
50/60 Hz (± 0,5%)
True sine
12 V
700 W
< 810 W (1 min)
< 1400 W
GFCI
• %
3 x LED
200 x 330 x 83 mm / 7,9 x 13 x 3,3 in
2,6 kg
CE, Safety: UL458, EMC, FCC
High frequency
10,5 V
12,5 V
16,5 V
14,5 V
70 A
< 1,5 A @ 12 V
< 0,1 A @ 12 V
100 A
25 mm² / 4 AWG
< 5%
All power factors allowed
-20 °C to 40 °C, derating > 40 °C
Fan
IP21 (if horizontally wall mounted)
Over temperature, over load, short
circuit, high/low battery voltage
Yes
ENGLISH
AC Master 24/700-120
28025700
100/110/115/120 Vac (± 3%) –
50/60 Hz (± 0,5%)
True sine
24 V
700 W
< 810 W (1 min)
< 1400 W
GFCI
• %
3 x LED
200 x 330 x 83 mm / 7,9 x 13 x 3,3 in
2,6 kg
CE, Safety: UL458, EMC, FCC
High frequency
21,0 V
25,0 V
33,0 V
29,0 V
35 A
< 0,8 A @ 24 V
< 0,06 A @ 24 V
50 A
16 mm² / 6 AWG
< 5%
All power factors allowed
-20 °C to 40 °C, derating > 40 °C
Fan
IP21 (if horizontally wall mounted)
Over temperature, over load, short
circuit, high/low battery voltage
Yes