NOTE
Use DRY operation when you want to reduce the humidity
l
in the room.
Once the room temperature reaches the set level, the unit
l
repeats the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set
l
to
or stops to prevent overcooling.
Dry operation is not possible if the indoor temperature is
l
15 °C or less.

FAN ONLY

If you want to make air circulate without any temperature control,
follow these steps:
1. Press the ON/OFF operation button and switch the air
conditioner ON.
2. Press MODE button until only the
the display.

ADJUSTING THE FAN SPEED

AUTOMATIC
Simply set the FAN selector to the
microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner starts
operating, the difference between the room temperature
and the set temperature is detected by the microcomputer
which then automatically switches the fan speed to the
most suitable level.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
TEMPERATURE IS
Cooling and
2 °C and over
dehumidifying
Between 2 and 1 °C
modes:
Below 1 °C
2 °C and over
Heating mode:
Below 2 °C
NOTE
The above mentioned data make reference to the
conditioner operating when the sensor on the remote control
unit is ON. (Refer to temperature sensor selector). If the
sensor on the indoor unit is being used then actual operation
will slightly differ from that described in the above tables.
The automatic speed is not available in FAN ONLY mode.
MANUAL
If you want to manually adjust speed just set the FAN selector
as desired.
High speed
Med. speed
NIGHT MODE
The NIGHT mode enables you to save energy.
l
1. Set the MODE selector to cool, dry or heat.
2. Press the NIGHT button.
3. The
button again to release the NIGHT function.
What does the NIGHT mode mean?
In this mode, the air conditioner will cool or heat the room
to the set temperature, and then the thermostat will make
the unit pause. After about 1 hour, the air conditioner will
automatically reset the set temperature as follows (also
refer to graphs).
Cooling and Dehumidifying
fan sign appears on
When the room temperature reaches the new set value,
the thermostat will cause the unit to pause. After about 1
hour the temperature will be raised by 1 °C in cooling, or
lowered by 1 °C in heating. This enables you to save energy
without sacrificing your comfort.
position.A
COOLING AND DEHUMIDIFYING
Setting temperature Room temperature
FAN SPEED
High
Medium
Low
High
Medium
Low speed
11
mark appears on the display. Press the NIGHT
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
1°C
1°C
1 hour 1 hour
TIME
Setting temperature
1 hour
Lowered by 1 °C
Raised by 1 °C
HEATING
Room temperature
1°C
1°C
1 hour TIME
EG