Product Identification - Technibel Climatisation REVE 245SCH2O Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CONDITIONS ACCORDING TO EN14511
COOLING Room Temperature
HEATING Room Temperature
COOLING MAX.Room Temperature
EG
HEATING MAX.Room Temperature
DEHUMIDIFING MAX.Room Temperature

PRODUCT IDENTIFICATION

This type of appliances are autonomous units and are
especially recommended to solve the problem of air
conditioning where you have no possibility or you don't
want to be connected to the outside.
The appliance can be installed also at inside walls or
anywhere else there is a water work.
The condenser is water cooled instead of air cooled like
the normal air conditioners; so the operation is noiseless.
The appliance is provided of two connections for the water
work (one for the water inlet and the other for the water
return into the unit) and one connection for condensate
drainage.
The water connection is on the back side of the appliance
where you can find two holes on the rear panel.
The unit can be simply hanged up at the wall or put on the
floor using the floor support kit (accessory on request).
You can use well water or municipal water in cities where
it is permitted; in case of installation of more units in the same
building, it would be recommended to install a cooling tower
in order to reduce the water consumption.
In any case, at the main water inlet of the water work, a
filter or water softener and a water flow rate control must
be installed.
The appliance is provided of an electrovalve on the water
outlet from the condenser; it is necessary to limit the water
consumption only during the compressor operation.
The appliance is also preset to replace a radiator, using
the boiler connection kit (accessory on request).
27°C dry bulb
19°C wet bulb
Water Inlet temperature
30°C
Water Outlet temperature
Inlet
35°C
20°C dry bulb
Water Inlet temperature
15°C
OPERATING LIMITS
32°C dry bulb
24°C wet bulb
MAX.Water Outlet temp.
Inlet
45°C
MIN.Room Temperature
16°C dry bulb
MIN.Temp.Acqua usc.
22°C
25°C dry bulb
MAX.Water Outlet temp.
Inlet
23°C
MIN.Room Temperature
10°C dry bulb
MIN.Water Outlet temp.
Inlet
5°C
32°C dry bulb
24°C wet bulb
MAX.Water Outlet temp.
Inlet
45°C
MIN.Room Temperature
16°C dry bulb
MIN.Water Outlet temp.
Inlet
22°C
STANDARD CONDITIONS WITH MUNICIPAL WATER SYSTEM
COOLING Room Temperature
Water Inlet temperature
Water Outlet temperature
HEATING Room Temperature
Water Inlet temperature
Water Outlet temperature
OPERATING LIMITS
COOLING MAX.Room Temperature
MAX.Water Inlet temp.
MIN.Room Temperature
MIN.Water Inlet temp.
HEATING MAX.Room Temperature
MAX.Water Inlet temp.
MIN.Room Temperature
MIN.Water Inlet temp.
DEHUMIDIFING MAX.Room Temperature
MAX.Water Inlet temp.
MIN.Room Temperature
MIN.Water Inlet temp.
2
27°C dry bulb
19°C wet bulb
18°C
36°C
Inlet
20°C dry bulb
18°C
Inlet
6°C
32°C dry bulb
24°C wet bulb
24°C
16°C dry bulb
12°C
25°C dry bulb
24°C
10°C dry bulb
12°C
32°C dry bulb
24°C wet bulb
24°C
16°C dry bulb
12°C