HOW TO SET THE PRESENT TIME

1. Press the button SEL TYPE three times.
The time indication alone flashes.
2. Press the SET H button until the present time hour is
displayed.
Press the SET M button until the present time minu-
tes are displayed. The display will automatically stop
flashing.
EG

COOLING

NOTE
Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1.Set the MODE selector to COOL
2.Press the ON/OFF button and switch the
air condioner ON.
3.Press the TEMP. buttons to set the desi-
red temperature (the temperature range
is between 32 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
4. Press the FAN button to select the fan speed.
NOTE
The air conditioner disposes of the condensate water automati-
cally at the HIGH and MEDIUM fan speed, on the contrary at
the LOW fan speed the condensate water is collected in the
tank.

DEHUMIDIFYING (DRY)

1. Set the MODE selector switch to "DRY"
2. Press the ON/OFF button and switch the air condioner
ON.
3. Press the TEMP. buttons to set the desired temperature
(the temperature range is between 32 °C max. and 16 °C
min.).
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
NOTE
Use DRY operation when you want to reduce the humidity
l
in the room.
During DRY operation, the fan speed is automatically set to
l
or stops to prevent overcooling.
Dry operation is not possible if the indoor temperature
l
is 15 °C or less.
The humidity of the room (condensate water) will be collected
l
in the internal tank of the air conditioner.

FAN ONLY

If you want to make air circulate without any temperature con-
trol, follow these steps:
1. Press the ON/OFF operation button and switch the air con-
ditioner ON.
2. Press MODE button until only the
on the display.
5
2
.
4
1
AFTER 5 SECONDS FROM THE REQUIRED TEM-
PERATURE SETTING THE DISPLAY WILL SHOW
THE ROOM TEMPERATURE AGAIN.
AFTER 5 SECONDS FROM THE REQUIRED TEM-
PERATURE SETTING THE DISPLAY WILL SHOW
THE ROOM TEMPERATURE AGAIN.
fan sign appears

ADJUSTING THE FAN SPEED

AUTOMATIC
Simply set the FAN selector to the
microcomputer automatically controls the fan speed
when the AUTO mode is selected. When the air conditio-
ner starts operating, the difference between the room
temperature and the set temperature is detected by the
microcomputer which then automatically switches the fan
speed to the most suitable level.
WHEN DIFFERENCE BETWEEN
ROOM TEMPERATURE AND SET
TEMPERATURE IS
Cooling and
dehumidifying
modes:
NOTE
3
The above mentioned data make reference to air conditioner
operating when the sensor on the remote control unit is ON.
(Refer to temperature sensor selector). If the sensor on the unit
is being used then actual operation will slightly differ from that
described in the above tables.
The automatic speed is not available in FAN ONLY mode.
MANUAL
If you want to manually adjust speed just set the FAN selector
as desired.
High speed
.

SLEEP MODE

The SLEEP mode enables you to save energy.
l
1. Set the MODE selector to cool or dry.
2. Press the NIGHT button.
3. The
mark appears on the display. Press the NIGHT
button again to release the NIGHT function.
What does the SLEEP mode mean?
In this mode, the air conditioner will cool or dry the room to the
set temperature, and then the thermostat will make the unit
pause. After about 1 hour, the air conditioner will automatically
reset the set temperature as follows (also refer to graph).
When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 1 hour the
temperature will be raised by 1°C. This enables you to save
energy without sacrificing your comfort.
Setting temperature
FAN SPEED
2 °C and over
Between 2 and 1 °C
Medium
Below 1 °C
Med. speed
COOLING AND DEHUMIDIFYING
Room temperature
1°C
1°C
1 hour
1 hour
TIME
position. A
High
Low
Low speed