Télécharger Imprimer la page

GALAGAR SMART 200 TIG PLUS Manuel Technique D'instructions page 21

Publicité

Les langues disponibles

Les langues disponibles

1.2. Volt-Ampere Characteristic
SMART 200 TIG PULSE welding machine has an excellent volt-ampere characteristic, whose graph is shown as the
following figure. The relation between the conventional rated loading voltage U2 and the conventional welding
current I2 is as follows:
When I2≤600A,U2=10+0.04I2(V); When I2¬>600A,U2=34(V).
2. INSTALLATION AND ADJUSTMENT
2.1 Parameters
Model
Model
Model
Model
Power Source
Rated Input Power (KW)
Rated Input Current (A)
Power Factor
Duty Cycle(40℃,10
minutes)
Max no-load Voltage(V)
Welding Current(Peak Current) Range(A)
Base Current Range (A)
Start Current Range(A)
Crater Current Range(A)
Pulse Frequency Range(Hz)
Pulse Width Range (
Up Slope Time(S)
Down Slope Time (S)
Pre Flow(S)
Post Flow(S)
Efficiency (%)
Protection class
Insulation class
Weight (Kg)
Dimensions of Machine (mm)
(L×W×H)
SMART 200 TIG PULSE
U
2
(V)
Volt-ampere characteristic
63
34
10
0
25%
30%
60%
100%
)
The relation between the
conventional loading
voltage and welding current
Working
point
600
SMART 200 TIG PULSE
1~220V±10%,50/60Hz
4.7(TIG)/5.5(MMA)
31(TIG)/34.5(MMA)
TIG
200A
130A
100A
5~200(TIG)/5~170(MMA)
I
2
(A)
0.8
MMA
170A
130A
100A
63
5~200
5~200
5~200
0.5~100
5~100
0~5.0
0~5.0
0~1.0
3.0~10.0
≥80
IP23
F
8
400*140*230
21