− Wait until the compressor has
come to a complete stop.
− Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
− Let the device and all air tools
and accessories used cool off.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts
remain
on
machine.
Compressor does not run:
•
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
•
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
•
Compressor
was
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
•
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
− Kompressor am Ein/Aus-Schalter
ausschalten; Ursache der Über-
hitzung beseitigen; etwa zehn
Minuten abkühlen lassen; Motor-
schutzschalter
drücken;
pressor
am
Ein/Aus-Schalter
erneut einschalten.
Compressor runs but does not build
up sufficient pressure.
•
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
•
Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
•
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
•
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
Danger!
Repairs to power tools must be car-
ried out by qualified electricians only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
8. Environmental Protection
The tool's packaging materials are
100 % recyclable.
Worn out machines and accessories
contain considerable amounts of valua-
or
in
the
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
stopped
by
Kom-
ENGLISH
13