Before Using For The First Time; Water Connection; Electrical Connection - Gaggenau RF463704 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en-us
Installation and connection

Before using for the first time

1.
Remove information material, adhesive tape and
protective foil.
2.
Clean the appliance.
~ "Cleaning" on page 26

Water connection

9
CAUTION
Installation and connection of the appliance must
be carried out by authorized technicians according
to the installation instructions supplied.
9
CAUTION
To avoid damage to the appliance and to ensure its
proper functioning, it should only be connected to
a drinking water system.
9
CAUTION
To avoid water damage, a shut-off valve must be
installed.
Water pressure of drinking water system
9
CAUTION
To avoid damage to the appliance, a pressure
relief valve must be installed between the drinking
water connection and the tubing, should the water
pressure exceed the maximum value.
Note: If the water pressure is too low, this will impair the
relevant functions of the appliance.
Min. 0.2 Mpa (2 bar / 29 psi)
Max. 0.8 Mpa (8 bar / 116 psi)
10

Electrical connection

9
CAUTION
Do not connect the appliance to electronic energy
saver plugs.
Note: You can connect the appliance to mains-controlled
and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national grid.
Sine-controlled inverters must be used for isolated
applications. Isolated applications, e.g. on ships or in
mountain lodges, are not directly connected to the
national grid.
1.
After installing the appliance, wait at least 1 hour
before connecting it to prevent damaging the
compressor.
2.
Check that the outlet was installed according to the
regulations and complies with the requirements.
Requirements for outlets
Outlet with
Protective conductor
Fuse
Maximum simultaneous load
Appliance
3.
Connect the appliance to an outlet near the appliance.
The outlet must also be freely accessible following
installation of the appliance.
9
WARNING
Risk of electric shock!
Never use multiple outlets, extension cords or
adapters.
The appliance must be grounded correctly.
Never cut through or remove the power cord's
third conductor (grounding conductor).
Risk of electric shock!
If the power cord is too short, never use
multiple outlets or extension cords.Instead,
please contact Customer Service.
110 V ... 120 V
60 Hz
10 A ... 16 A
6 A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rf463705

Table des Matières