FUXTEC FX-4MS142 Mode D'emploi Original page 52

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Spark plug maintenance
To ensure regular operation of the engine, the ignition distance of 0.6 - 0.7
must be maintained and free of carbon deposits.
1 Carefully remove the spark plug connector. Do not pull on the cable but directly on the plug.
2 Use the spark plug wrench supplied to unscrew the spark plug.
3 Visually check the spark plug for damage or electrode burn-off.
Remove the carbon deposits.
cleaning of coal deposits
4 Check the gap with a feeler gauge and bend the electrode to the
correct distance of 0.6 to 0.7mm
5 Check the spark plug washer and screw the spark plug in the first 2-3
threads manually first.
6 Mount the ignition cap back on the spark plug
WARNING
The spark plug must be screwed down tightly; otherwise, the engine runs hot and is damaged.
Maintenance during storage of the machine
If the engine is not to be used for a more extended period, the following maintenance must be carried
out:
1 Open the fuel filler cap and drain the fuel completely. Operate the primary pump until the gasoline is
completely removed from the fuel lines.
2 Open the oil cap and completely drain the lubricating oil as described
3 Adjust the crankshaft to top dead center (by pulling the starter) to ensure that the air does not cause
corrosion
4 Wipe off all oil stains and clean the cooling fins. Place the device in a clean, dry, and well-ventilated
place.
Original Bedienungsanleitung FX-4MS142_de_en_fr_ita_rev01
Removing
the
plug
Spark plug window
spark
Spark plug
52
Spark
plug
connector
0.6~0.7mm

Publicité

Table des Matières
loading

Table des Matières