Attention! Only use the unit in conjunction with the OASE safety transformer UST 150 (not included in our scope of
delivery). Install the safety transformer at a flood protected place and provide a minimum spacing of 2 m from the pond
edge. Never open the unit housing or its attendant components, unless this is explicitly mentioned in the operating
instructions. Always disconnect the power supply of all units located in water and of this unit prior to performing work
on the unit! For your own safety, consult a qualified electrician if you have questions or encounter problems!
Set-up and start-up
The unit comes without bulbs and transformer. Please refer to „Bulb replacement" when fitting the bulb. When set up
above the water level, maintain a safety distance of at least 50 cm from combustible material. Ensure a safe seating.
Do not cover the unit. Danger of fire! A swivel bracket (4) can be fitted to the spotlight by means of a screw connection.
Position the unit such that it does not present a hazard for anybody. When fitting in the pond, fasten the unit on a
suitable base by means of the swivel bracket. The ground stake (5+6) can be used when installing the unit out of the
water. Connect the power plug of the spotlight to the socket of the transformer bush (2+3). Connect the transformer to
the power supply. Check the spotlight function.
Replacing the bulb (1)
Adhere to the safety instructions! Disconnect the power! Undo the screw-connection of the top section. Ensure that no
moisture can enter the unit. Remove the top section and the glass, clean, if necessary. Take the bulb out of the hous-
ing. Important! Only original bulbs from OASE may be used. Insert new bulb (do not touch, use a cloth or similar).
Check the O-ring and replace, if damaged. Reassemble the unit in the reverse order, connect to the power supply and
perform a function check.
Cleaning
Adhere to the safety instructions! Carry out the work steps as specified under 'Replacing the bulbs'. Only use water
and a soft brush. Ensure that no moisture can enter the unit.
Disposal
Dispose of the unit in accordance with the national legal regulations.
S
Malfunctions
Malfunction
Lamp does not light up
Light intensity decreases
Water in the spotlight housing
Light flickers
Remarques concernant cette notice d'emploi
Avant la première utilisation, lire attentivement cette notice d'emploi et se familiariser avec l'appareil. Respecter impé-
rativement les indications de sécurité relatives à une utilisation correcte et en toute sécurité.
Utilisation conforme à la finalité
Le projecteur halogène Lunaqua 10, dénommé par la suite «appareil», avec une ampoule halogène de 75 W max. est
réservé pour une utilisation avec des installations à jet d'eau et des bassins, et pour une température de l'eau allant de
+4°C à +35°C, et une profondeur d'immersion allant jusqu'à 4 mètres, ainsi qu'en dehors de l'eau avec une ampoule
halogène de 50 W.
Utilisation non conforme à la finalité
En cas d'utilisation non conforme à la finalité et de manipulation non appropriée de cet appareil, des risques pour les
personnes peuvent en résulter. Toute utilisation non conforme à la finalité entraîne l'annulation de notre responsabilité
ainsi que de l'autorisation d'exploitation générale.
Déclaration du fabricant CE
Nous déclarons la conformité par rapport à la directive basse tension (73/23/CEE). Les normes harmonisées suivantes
ont été appliquées :
EN 60598-2-7, EN 61558-1, EN 61558-2-6, EN 60825-1
Cause
Power supply interrupted
Bulb defective
Bulb contacts corroded
Lamp glass soiled
Seal defective
Contacts corroded
Remedy
Check power supply
Replace bulb
Clean contacts
Clean
Check sealing rings and replace, if necessary
Clean lamp pins
Signature:
-
F
-
-
F
-
7