User Manual
Installation
1. Connect the Transmitter Unit to the source device using a VGA cable.
2. Connect the Receiver Unit to the display using a VGA cable.
3. Connect the Transmitter and Receiver Units together using Cat.6 UTP or higher cable at the desired
length. Switch on all connected devices. The installation is now complete.
Please note: some monitors are more sensitive to the sync mode setting. In this scenario, please use
STP Cat.X cabling.
Operation
Sync Mode Selection (Transmitter)
▪
On the Transmitter Unit, a small switch allows for control over the system two sync mode option.
▪
For modern monitors, it is advised that the switch should be set at Mode 1 for optimum stability.
▪
For legacy monitors including CRTs, it is advised that the switch should be set at Mode 2 for
optimum stability.
▪
If there are any stability issues, please try the opposing sync mode
Sync Filter Dipswitch (Receiver)
▪
On the Receiver Unit, a Sync Filter dipswitch allows for adjustment to ensure a stable signal.
▪
Please adjust accordingly for which option provides the best stability for the connected display.
1
2
3
4
5
↓
↓
↓
↓
↓
↑
↓
↓
↓
↓
↓
↑
↓
↓
↓
↓
↓
↑
↓
↓
↓
↓
↓
↑
↓
↓
↓
↓
↓
↑
Level 0 (Min)
Level 1
Level 2
Level 3
Level 4
Level 5 (Max)