10. Faults
Problem
No output voltage
Display off
No output voltage
Display on
[OVERLOAD] led lights up Sparking or short-circuit in
Table 1 Faults
11. Repair
Warning:
When carrying out work on the equipment: de-energise the equipment.
-
-
Repairs must be made by a skilled electrical engineer.
When opening the equipment, you may come into contact with parts under dangerous
-
voltages.
SIMCO recommends that you return the generator if repairs are required.
Pack it properly and clearly state the reason for return.
97.52.09.0230 ECM 30 /ECM 60
Cause
Mains voltage < 85V AC
Fuse at the rear of the unit
is defective
High voltage generator
defective
A setpoint has not been
given
(note, in [(UN)LOCKED]
position this comes from
the [ ] / [ ] keys and in
[REMOTE] via the Sub-D
connector)
Remote on/off dipswitch
has been switched on, but
signal is not sent to switch
the generator on
Press the [RUN] key to
switch the generator on
High voltage generator
defective
connected equipment
Generator overloaded
35
Remedy
Restore mains voltage
Replace fuse
Send generator for repair
Give setpoint
Switch off remote on/off
dipswitch
or send signal to the Sub-D
connector to switch the
generator on
Send generator for repair
Check connected equipment
Reduce setpoint
Increase distance between
charging bar / electrode and
material
01/08