9 Faults

Warning:
- Disconnect the power supply before carrying out work on the unit.
Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
Table 2, faults
Problem
LEDs on
CMM Easy do not
light up
LEDs do not light
up orange, keep
flashing green
LEDs light up red
LEDs flashing red
LEDs flashing
red/green
CMMEasy_UM_9752098500_NL_D_GB_F_V2_0
Possible cause
No supply voltage
Wiring fault
Generator earth wire not
connected
No signal on the
Remote On/Off input
High voltage set too low
Label or labels between
electrodes and earth are too
small or not present,
arcing between electrode and
mould
Output voltage set too high,
arcing on electrode
Short circuit between electrode
or HV cable and earth
Supply voltage too low
"Cycle OK" output overloaded
Generator overheated
Solution
Switch on 24 V DC supply
voltage
Locate fault and remedy, see 5.3
Connect generator earth wire,
see 5.3
Connect
24 V DC (±3 V)
"Remote On/Off" input
Increase output voltage by
increasing setpoint (5.3/6.2)
Check presence or size of
label(s)
Insulate electrode or increase
distance to (part of) mould
Reduce output voltage by
reducing setpoint or increasing
distance to earth
Locate short circuit and eliminate
Restore
21–27 V DC
voltage on M12 connector
Eliminate overload (24 V DC >
50 mA).
Ambient temperature < 55ºC
Eliminate overload; see above
solutions
to the
supply
36