METHODS OF OPERATION
This Nailer is equipped with the push lever and does not operate unless the push lever is
depressed (upward position).
There are two methods of operation to drive nails with this Nailer.
They are:
1.
Intermittent operation (Trigger fire):
2.
Continuous operation (Push lever fire):
(1) Intermittent operation (Trigger fire)
Use the SINGLE ACTUATION MECHANISM setting.
● Unlike the FULL SEQUENTIAL ACTUATION MECHANISM, please
note that the SINGLE ACTUATION MECHANISM of this Hitachi
nailer will drive a nail each time the push lever is pressed against
the wood as long as the trigger is pressed.
● For intermittent operation, set the switching device to the upward
position completely. (i.e. Set to SINGLE ACTUATION
MECHANISM.)
● To avoid double firing or accidental firing due to recoil.
1) Set the switching device to SINGLE ACTUATION MECHANISM.
2) Pull the trigger rapidly and firmly.
1 Set the switching device to the upward position (to set to SINGLE ACTUATION
MECHANISM).
(Set the switching device to the upward position completely as shown in the
diagram. Otherwise, it will be set to CONTACT ACTUATION MECHANISM.)
2 Position the nail outlet on the workpiece with finger off the trigger.
3 Depress the push lever firmly until it is completely depressed.
4 Pull the trigger to drive a nail.
5 Remove finger from the trigger.
To continue nailing in a separate location, move the nailer along the wood, repeating
steps 2 - 5 as required.
1 Upward position
WARNING
Valve Bush
Switching Device
4
3
Push Lever
Trigger
English
19