Télécharger Imprimer la page

Hansgrohe Metropol 32551000 Mode D'emploi / Instructions De Montage page 5

Publicité

Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Assembly see page
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page )
Flow diagram
(see page )
Hand shower
Bath Spout
Operation (see page
Adjustment (see page )
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Maintenance check valve
(see page
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Cleaning (see page
closed brochure
Spare parts (see page
)
)
) and en-
)

Publicité

loading