GBC5137 HeatSeal H535 Manual EU
Advanced use
Control Panel LCD
The following information is displayed on the LCD:
Memory/Selection Setting Mode
To save a specific speed and temperature to one of the five memory
sets (SEL 1, SEL 2, SEL 3, SEL 4, and SEL 5).
Press
until you are in memory mode: 'SEL 1' appears on the
1
display. Press
or
Press
for a longer time to save the current speed and
2
temperature to the memory number you selected. When saving is
successful, MEMORY symbol blinks and the machine beeps.
To use a memory, select a memory number (see point 1) and
3
press
for a longer time. When the memory number is
selected, the machine beeps and the temperature appears on the
display. The machine then is loaded with the set temperature and
speed and begins warming up or cooling down.
Please note the 5 memories by default are:
SEL 1: Copy Paper 75 mic.
SEL 2: Brochure Paper 75 mic.
SEL 3: Photo Paper 75 mic.
SEL 4: Copy Paper 125 mic.
SEL 5: Brochure Paper 125 mic.
Quick laminating guide
1. Preset Mode
Press
to select pouch thickness
a
(=mic.) and appropriate paper type
(section). Speed and temperature adapt
automatically to selection. The machine
warms up.
b
When the machine is warm, ready
symbol appears on display and you can
laminate.
6
20/12/05
to select another memory number
2. Manual Mode
(to change speed and temperature manually):
Select one of the preset modes (see point
a
1)
b
Press
display. Press
Press
c
display. Press
17:15
Page 6
Temperature Manual Setting Mode
Press
to choose TEMP mode when TEMP shows.
1
2
Press
or
to increase and decrease temperature by 5°C.
Temperature can be adjusted to 160°C.
Wait until the Ready symbol appears for ready to laminate.
3
4
To switch the temperature unit between °C and °F, press
simultaneously. The temperature value and temperature unit
will change accordingly.
Speed Manual Setting Mode
Press
to choose SPEED mode.
1
2
Press
or
to set a new speed. There are many speed
settings.
Counter Mode
1
Press
to choose COUNTER mode.
The current counter number shows up.
2
The initial counter number is 0000. Press either
3
reset the counter number to 0000.
3. Selection/Memory Mode
(to save specific temperature and speed
in memory):
until temperature appears on
or
to modify it.
until speed (SP) appears on
or
to modify it.
or
Select either a preset or manual mode
a
Press
until 'SEL 1' appears on the
b
display. Press
to select another
memory number.
c
Press
for longer time to save current
mode to selected memory number.
To use a saved memory, select the
d
memory number (see point b) and
press
for a longer time.
and
to