ENGLISH
Inspection
To maintain operational reliability, carry out a visual inspection
of the unit, including the pipe connections, once a month.
MAINTENANCE
WARNING!
Before carrying out any work, pull out the mains plug and ensure
that the power supply to the unit cannot be switched on again by
anyone else.
WARNING!
Check the mains cable for signs of mechanical and chemical
damage. Damaged or kinked cables must be replaced by the
manufacturer.
The system must be cleaned annually and the intake filter
(JP50332) replaced. Non-return valves in the compressor unit
must be replaced every 2 years.
To ensure continued reliability of service, we recommend that
you take out a service contract.
CONTROL
The system is configured via the control display.
The menu items, settings and values are selected with the "ar-
row buttons" ▲ ▼ and confirmed by pressing the -OK- button.
Use the -ESC- button to exit the menu.
First use
When using for the first time, and after a reset, the time and
date must be set.
Language. The standard language is German. The arrow but-
tons can be used to switch to English, French, Dutch, Swedish
or Polish. Pressing -OK- confirms the selection.
Time. Each flashing digit must be selected with the arrow but-
ton and confirmed with -OK-. Once the full time has been set,
a "Time OK?" query follows. Confirm with -OK- or return with
-ESC-.
Date. Each flashing digit must be selected with the arrow but-
ton and confirmed with -OK-. The day of the week is set auto-
matically. Once the full date has been set, a "Date OK?" query
follows. Confirm with -OK- or return with -ESC-.
Standard display
PPCSZ
20:50
Pipe1 40 06.04
PPCS with fixed time,
pipe1, 40 minutes until it starts
Factory default setting
Fixed times: 8.00hrs and 21.30hrs with 5 minutes run-time.
Current data.
By pressing -OK- you can read off the operating hours of the
pressure pipe cleaning system (PPCS) and the pressure pipe
ventilation (PPV), the last starting time, temperature, current
12
consumption, operation of the system, and software.
Modes of operation.
In the main menu, the arrow buttons can be used to access the
operating modes menu. This menu allows you to set the oper-
ating times of the unit on the basis of various parameters.
Manual mode.
In manual operation, the components such as the pressure
pipe cleaning system (PPCS), the pressure pipe ventilation
(PPV), the pump sump ventilation (PSV), the heating and the
ventilation can be set individually by hand.
NOTICE! Pumping also takes priority over compressor operati-
on during manual operation.
System settings.
In the main menu, the arrow buttons can be used to access
the system menu, where individual settings and values can be
changed.
Logbook.
In the main menu, the arrow buttons can be used to access the
log, where all error messages are recorded with the date and
time. The most recent error message is shown on the display,
and the arrow buttons can be used to scroll through previous
error messages.
OPERATION MODES -OK-
You can now select various sub-menus with ▲ ▼ . Once you
press -OK-, you will be asked to enter a password.
The factory default setting is "0000". Each of the four digits
must be confirmed with -OK-. This means that in the case of
the factory default setting, for example, you will have to press
-OK- four times. You are now in the relevant sub-menu.
Before carrying out any settings for component, it is neces-
sary to change the component concerned from "inactive" to
"active".
▲ ▼ PPCS-fixed time -OK-
In this menu, you can set fixed times and running times for a
maximum of four pipes to be flushed. It is possible to set up
to ten times for each pipe. In addition, days of the week can
be selected: Mon-Fri (WK), Sat-Sun (WE), Mon-Sun (ALL) Each
flashing digit must be selected with the arrow button and con-
firmed with -OK-.
Flushing pipes (1-4) -OK-
Times for pipe (1-4) -OK-
Pipe x time y (1-10) -OK-
△▽ Starting time y -OK-
△▽ Running time y -OK-
△▽ Act. Days y -OK-
Press -ESC- to return to the previous level. If you wish to delete
a time y again, then in the first item of the starting time select
the x and press -OK-. In the display, the time is no longer dis-
played, and "OFF" now appears
▲ ▼ PPCS-pump control -OK-
In this option, the pressure pipe is flushed out subject to the
pumping operations. If the amount of water is sufficiently