Télécharger Imprimer la page

Maintenance; Ordinary Maintenance; Periodic Maintenance - Corghi ERCO 500 Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

9 CHAPTER 9 - MAINTENANCE
Only trained personnel who knows how the lift works, must be allowed to service
the lift.
To service properly the lift, the following has to be carried out:
 use only genuine spare parts as well as equipment suitable for the work required;
 follow the scheduled maintenance and check periods shown in the manual;
discover the reason for possible failures such as too much noise, overheating, oil blow-by,
etc.
Refer to documents supplied by the dealer to carry out maintenance:
 functional drawing of the electric and hydraulic equipment
 exploded views with all data necessary for spare parts ordering
list of possible faults and relevant solutions.
Before carrying out any maintenance or repair on the lift, disconnect the power
supply, padlock the general switch and keep the key in a safe place to prevent
unauthorized persons from switching on or operating the lift
9.1

ORDINARY MAINTENANCE

The lift has to be properly cleaned at least once a month. Use self-cleaning clothes.
The use of water or inflammable liquid is strictly forbidden
Be sure the rod of the hydraulic cylinders is always clean and not damaged since this may result in
leakage from seals and, as a consequence, in possible malfunctions.
9.2

PERIODIC MAINTENANCE

Every 3 months
Hydraulic circuit
Foundation bolts
Hydraulic pump
Safety system
Every 6 months
Oil
Every 12 months
General check
72
 check oil tank level; refill with oil, if needed;
 check the circuit for oil leakage.
 Check seals for proper conditions and replace
them, if necessary;
 check bolts for proper tightening
 verify that no noise changes take place in the pump
of the control desk when running and check fixing
bolts for proper tightening
 check safety devices for proper operation
 Check oil for contamination or ageing.
Contaminated oil is the main reason for failure of
valves and shorter life of gears pumps
 verify that all components and mechanisms are not
damaged

Publicité

loading

Ce manuel est également adapté pour:

Erco 500fErco 505Erco 505f