Preliminary procedures
Note: The BASIC configurations can be assigned manually
in BASIC mode (as described below) or ADVANCED mode
with the SaveProg software complete with interface, installed
on a PC.
All CONFIGURATION operations must be performed with
the indoor station on standby.
The indoor stations, after being installed as shown in the pre-
vious chapters, must be configured by assigning the ID code.
The ID code is unique for each appliance.
Manual ID code configurations
The Basic indoor station configurations are as follows:
- Configuration of the ID code.
- Or configuration of the secondary ID code, to be done
when an indoor station needs to be associated with a Mas-
ter indoor station.
Configuration of the ID code
The identification code is programmed with a configured
MASTER entrance panel.
An indoor station with no ID code configuration beeps three
times when the
button is pressed
1) Press and hold down the
2) Press the
button too and keep them pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
button within 5s and keep it pressed un-
til you hear a warning tone on the indoor station and the
communication is activated between the indoor station
and the external electronic unit. If more than 5s passes
without the
button being pressed, steps 1, 2 and 3
must be repeated.
5) Release the
button.
6) With a timeout of 30s associate the ID code from the exter-
nal electronic unit:
- if using an alphanumeric entrance panel, enter the pri-
mary ID code and confirm with the
- if using an entrance panel with buttons, press the button
you want to use for calling the indoor station.
Note: If the system already contains an indoor station with
the same associated identification code, the entrance panel
emits a low tone and the process must be repeated from the
start in order to assign a different code.
EN
button.
button.
Configuring the secondary ID code in
automatic mode
The secondary identification code is configured when the
same call has to activate multiple indoor stations at the same
time (max 4 composed of 1 Master and 3 secondary ones).
You need to define a Master indoor station which can be as-
sociated with up to 3 indoor stations with a secondary ID. At
most 50 Master ID codes can be configured in this mode.
1) Press and hold down the button
station.
2) Press the
button too and keep them pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
and
them pressed until you hear a warning tone on the indoor
station and the communication is activated between the
indoor station and the external electronic unit. If more than
5s passes without the
steps 1, 2 and 3 must be repeated.
5) Release the
and
6) With a timeout of 30s associate the ID code of the Master
from the external electronic unit:
- if using an alphanumeric entrance panel, enter the Mas-
ter ID code and confirm with the
- if using an entrance panel with buttons, press the button
you want to use for calling the indoor station.
Note: The SaveProg software can be used to program acti-
vation of the chimes of all the monitors and switching on the
monitor of only the master unit.
Note: To delete from a group, the configuration deletion pro-
cedure described in the "Default data restore procedure" sec-
tion must be performed.
Default data restore procedure
1) Press and hold down the button
2) Press the button
too and keep them pressed until the
button
starts blinking.
3) Release the buttons.
4) Press and hold down the button
5) When an audible warning is emitted (during the sound)
release the button
and briefly press the button
The indoor station configurations have now been de-
leted. Make sure that the configurations have been
successful
deleted
by
The indoor station should emit an audible warning (3 beeps).
of the Master indoor
buttons simultaneously and keep
and
buttons being pressed,
buttons.
button.
.
pressing
the
button.
.
.
15