5. Connection
The
providing 24 V DC SELV. The power supply must ensure safe separation between
the primary and the secondary side.
The blind/shutter motor is to be connected to the motor terminals of the 24 V insert.
If the motor runs in the wrong direction, the connecting wires must be interchanged.
Connection of
Connection of extension inputs
Extension inputs '1' and '2' may only be connected to 24 V DC SELV.
The sense of running of the blind/shutter motors is dependent on the polarity of the
extension input connection. The figure on the left shows the sense of running of the
motor for the two different polarities.
As long as an UP signal is present on the extension input with terminal '1'
terminal '2'
by automatic control.
Important:
Up
If the motor runs in the wrong direction when controlled from the extension unit (in
the sense opposite the one initiated by local operation) the extension input
Down
connections must be interchanged.
28
®
RolloTec
insert 'Komfort' for DC drives
must be supplied from a power supply
RolloTec
®
insert 'Komfort' for DC drives
, the blind/shutter cannot be operated manually on the device itself or
and
GB
Connection of
RolloTec
®
insert 'Komfort' for DC drives
extension unit (blind/shutter pushbuttons with mecanical interlock).
With blind/shutter pushbuttons, the insert cannot be operated in the maintained-
contact mode (continuous run). The blind/shutter must be moved to the desired
position by depressing and holding the pushbuttons.
If this is not acceptable, a blind/shutter control switch with mechanical interlocking
must be used.
The
RolloTec
®
insert 'Komfort' for DC drives
can be operated from a mechanical
extension only if the insert and the extension are supplied from the same 24 V
power supply unit. Only in this case are the insert and the extension on the same
potential so that it is sufficient to switch only the
potential via the mechanical
extension.
If the extension is supplied (e.g. in a central control configuration) from another
power supply unit, it is necessary to use a
RolloTec
®
insert 'Komfort' for DC drives
permitting connection of both extension inputs (see fig. on page 30).
Connection of
RolloTec
®
insert 'Komfort' for DC drives
insert.
Important:
As long as an UP signal is present on the extension input with terminal '1'
terminal '2'
, the blind/shutter cannot be operated manually on the device itself or
by automatic control.
with mechanical
with 24 V DC extension
and
29