Accessed by the code 23, then the browsing works in the same way as the regular setting mode.
The intervention on the advanced setting shall be done by a trained professional. Any mistake can
disturb the work of the device and is under its author's responsibility.
Step n°
Display
PASSW ?
Enter the password to go through the advanced set-
0
00
ting.
Enable / disable the proportional regeneration (the
PROP R
1
Scope of Delivery sheet specifi es the integration of
On
this function in the softener).
Modify the softening capacity of the device, which has
CAPA
2
been automatically set once the resin volume was se-
80
lected (step 3 of regular setting).
VOL OK
Volume of softened water (read only info). Here: 856
3
8 56
liters.
PEAKFL
Peak fl ow recorded since the last regeneration (read
4
10 68
only info). Here: 1068 liters per hour.
N REGE
Number of regenerations done since the commissioning.
5
48
May be reset.
CHLOR
6
Enable / disable the chlorination function
Off
ALARME
7
Salt lack alarm enabled / disabled
Off
SAFE L
Safe level value = remaining capacity value which trig-
8
2 50
gers the regeneration once reached.
REGE T
9
Time of regeneration start.
2:00
PRESS
Water network pressure. To be set for proportional re-
10
4
generation purpose.
Frequency of the full regenerations (to prevent from
FUL RG
loss of capacity occurring with time), for the softeners
11
5
with proportional regeneration function. Here: one full
regeneration every 5 regenerations.
Setting of each regeneration step durations.
The followings step durations can be adjusted (one
12
STEPS
submenu for each): Backwash (BACKW) ; aspiration
(ASPI) ; fast rinse (FAST) ; brine preparation (propor.
regen.) (BRINE) ; tank refi ll (propor. regen.) (REFILL)
FORCED
Turn ON or OFF the automatic forced regeneration after
13
NONE
a long time without water consumption
RESET
14
Reset back on initial factory settings
OFF
Notice technique ADOUCISSEUR A27-A6X - Manual SOFTENER A27-A6X code P0011144 - Rev 0 - 29/02/2016
ADVANCED SETTING
Purpose
Action
êé to change
OK to confi rm
çM to cancel
ê to turn on / off
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
çM to go to next step
çM to go to next step
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
êé to change
OK to confi rm
çM to cancel
OK to enter the menu,
otherwise çM then
êé to change
OK to confi rm
çM to cancel
êé to activate
OK to confi rm
çM to cancel
êé to turn ON
OK to confi rm (twice)
çM to cancel
31