ROUTINE & ADVANCED MAINTENANCE
Routine maintenance
This maintenance level may be handled by anybody having carefully taken into account the following
guidelines. It is highly recommended to follow them so that the softener keeps its performances in
the long term.
Maintenance guidelines
Check the salt level in the tank
Setting check
Time change
Change the fi lter element of the fi lter (7)
There are various models of fi lters. To change
the fi lter element:
•
Cut the water upstream and downstream
•
Let the pressure drop with the purge screw
upon the fi lter
•
Unscrew the fi lter transparent bowl and
remove the fi ltering consumable
•
Replace it by a new one
•
Screw the bowl back, tightening it gently
Overall checkup, cleaning, disinfection
•
Use the AQA clean pack or equivalent,
providing the adapted products and specifying
their proper use in its manual.
•
Check the raw water hardness upstream
and the softened water hardness downstream
of the device, using the analysis kit.
32
Notice technique ADOUCISSEUR A27-A6X - Manual SOFTENER A27-A6X code P0011144 - Rev 0 - 29/02/2016
Frequency and consumables
Every week, or if alarm. Refi ll as far as needed.
Check the time on the display.
The seasonal time change is not automatic.
Change the time following the procedure ex-
plained in the chapter SETTING.
Every 6 months or more often if you notice a
signifi cant pressure drop at the taps.
Once a year:
- Pack AQA clean including:
•
Hardness kit
•
Cleaning liquid
•
Disinfecting liquid
- Standalone hardness kit
- Standalone cleaning liquid