Environment features
Features
Power voltage
Maximal pressure
Minimal pressure
Minimal water temperature
Maximal pressure temperature
Ambient air minimal temperature
Ambient air maximal temperature
Operational features
Resin volume
Salt consumption per regeneration
Softening capacity for 15°f hardness
drop of (around 8.5 °dH)
Softening capacity for 20°f hardness
drop of (around 11 °dH)
Softening capacity for 25°f hardness
drop of (around 14 °dH)
Softening capacity for 30°f hardness
drop of (around 17 °dH)
Softening capacity for 35°f hardness
drop of (around 19.5 °dH)
Softening capacity for 40°f hardness
drop of (around 22.5 °dH)
Average water consumption per re-
generation
Electrical consumption in service
Electrical consumption in regeneration
The above data are given for a network water pressure of 4 bars and the factory settings.
Notice technique ADOUCISSEUR A27-A6X - Manual SOFTENER A27-A6X code P0011144 - Rev 0 - 29/02/2016
TECHNICAL FEATURES
liters
5
kg
0,65
liters
1000
liters
750
liters
600
liters
500
liters
400
liters
350
liters
50
VA
VA
Unit
All devices
V
230 +10% / -15%
Hz
50/60 Hz
bar
bar
°C
°C
°C
Frost free
°C
10
16
20
1,25
2,00
2,50
2300
5300
6000
1750
4000
4500
1400
3200
3600
1150
2600
3000
1000
2200
2500
850
2000
2200
60
70
100
6
25
7
1,5
1
35
40
22
28
2,75
3,50
6600
8400
4900
6300
3900
5000
3300
4200
2800
3600
2400
3100
100
120
35