3.4 Design and operating mode
The pumping station is equipped with several horizontal and vertical inlet openings for 40/50/100/110/125 mm external diameter piping
The motor-pump assembly conveys the pumped fluid in the discharge pipe with an external diameter of 50 mm (DN 40) in maceration
version or external diameter of 63 mm (DN 50) in vortex.
The ventilation duct (external diameter 75 mm) allows the tank to always remain at atmospheric pressure (2 ventilation holes are avai-
lable on the SANIFOS
250 and SANIFOS
®
3.4.1 SANIFOS
110 and SANIFOS
®
Operating mode:
Effluents enter the pumping station
through the horizontal and vertical
inlet openings.
They accumulate in a gas-tight,
smell-proof and watertight plastic
tank.
As soon as a certain fill level is
detected by the float switch, the
pump starts up automatically.
Effluents are automatically raised up
to flow into the drain pipe.
As soon as the effluent level reaches
a minimum effluent level in the tank, detected by the float switch, the pump switches off automatically.
3.4.2 SANIFOS
500
®
Operating mode:
Effluents enter the pumping station through the horizontal and vertical inlet openings.
They accumulate in a gas-tight, smell-proof and watertight plastic tank.
When the effluent enters the tank, the low float rises and then the high float rises to
reach the pump's activation level.
The pump starts up and the effluents are lifted automatically to flow into the drain pipe.
As soon as the effluent level reaches a minimum effluent level in the tank, detected by
the low float switch, the pump switches off automatically.
SANIFOS
500 contains 2 pumps that operate alternately. In case of malfunction, the
®
alarm is triggered by the alarm float and the 2 motors operate simultaneously.
If one of the 2 pumps is defective, the other one takes over.
500 and 1 ventilation hole on the SANIFOS
®
250
®
SANIFOS
110
®
SANIFOS
250
®
110 pumping station).
®
UK
SANIFOS
250
®
SANIFOS
500
®