Step 6: Electrical Requirements, Connection & Grounding
•
Prior to installing appliance, always disconnect
appliance electrical supply cord, if so equipped,
from wall receptacle. If appliance is hard-wired to
power supply, disconnect power to unit by turning
off the proper circuit breaker or disconnecting the
proper fuse. Lock service panel to prevent power
from being turned ON accidentally.
Chart B: Electrical Supply Circuit Requirements
MODEL TYPE
30"
36"
48"
•
A neutral supply wire must be provided from the
power source (breaker/fuse panel) because criti-
cal range components, including the surface
burner spark re-ignition module, require 120 VAC
to operate safely and properly. An improper 120/
240 VAC power supply will cause malfunction,
damage this appliance, and possibly create a
condition of shock hazard. If the correct power
supply circuit is not provided, it is the responsibil-
ity and obligation of the installer and user to have
proper power supply connected. This must be
accomplished in accordance with all applicable
local codes and ordinances by a qualified electri-
cian. In the absence of local codes and ordi-
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psig (3.5 kPa.).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system
during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5 kPa.).
When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 6" W.C.
(14.9 mb) for natural gas or 11" W.C. (27.4 mb) for propane.
Do not attempt any adjustment of the pressure regulator.
Dual Fuel range models can be connected or hard-
wired to the power supply as described on Page 15.
VOLTAGE
CURRENT
240/208 VAC
35 Amps
240/208 VAC
35 Amps
240/208 VAC
50 Amps
•
•
•
CAUTION
13
FREQUENCY
60 Hz.
60 Hz.
60 Hz.
nances, the power supply connection shall be in
accordance with the National Electric Code.
Observe all governing codes and ordinances
when grounding. In the absence of these codes
or ordinances observe National Electrical Code
ANSI/NFPA No. 70 current issue. See Pages 15
and 16 for grounding method.
Electrical wiring diagrams and schematics have
been placed in the toe kick area of the range for
access by a qualified service technician.
The ranges are to be connected to a 240/208
VAC power supply.
PHASE
Single
Single
Single