Maintenance And Service - Franklin Electric SubStart SC Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
External Switch
A float, pressure or any other external switch can be
used to power the SubStartSC. Remember to leave
the ON/OFF switch in the SubStartSC in the ON
position if an external control switch is used.
Managing ON/OFF switching activity
Your submersible electric motor accumulates a
certain amount of heat each time it is switched on. It
must run for a period of time during which it has the
opportunity to dissipate the heat. If too many starting
cycles are called for your motor and/or pump may be
damaged. Observe the starting specifications of the
motor.

Maintenance and service

The SubStartSC is maintenance free and requires no
maintenance or service. The control box contains no
serviceable parts.
4
Trouble shooting
Condition / Fault
Motor / pump does
not switch on
Motor / pump does
not switch off
Motor / pump
switches on and off
repeatedly
Overload trips
repeatedly
Cause / Remedy
Loss of power - check
supply voltage (Are other
appliances working? )
Damaged switch - con-
tact supplier
Overload tripped -
reset overload
Damaged switch - con-
tact supplier
Faulty pressure switch
or float switch -
contact supplier
Pump locked - debris
may have entered the
pump. Remove motor -
pump from the borehole
and clean pump
Cable damage - the
drop cable may have
been damaged. Check
cable for damage.
GB

Publicité

Table des Matières
loading

Table des Matières