Storage, transport and disposal
Storage
Do not remove the control gear from its original
packaging until the time of installation.
Keep this manual with the control gear for future
use.
Do not store in direct sunlight or close to any
heat source.

Transport

Observe temperature and humidity specifications
during periods of transport.
(-25°C to +55°C without condensation).
Unpacking
After unpacking, check for physical damage that
may impact on the safety of the control gear such as
a damaged enclosure, dislodged cable glands etc.
Observe the local regulations and dispose of any
packaging material accordingly.
Disposal
Observe the local regulations and dispose of any
control gear accordingly. This product contains
electrical and electronic components and should be
disposed of accordingly.
Technical specifications and
model parameters
The tables below summarize the technical attributes,
specification and model parameters of the SubStart-
SC
range. Models may differ with respect to current
®
overload characteristics, detailed capacitor sizes and
motor currents. The connector terminals are suitable
for copper (Cu) wire.
Model Parameters
Motor
Rating
1~PSC / 230V 50Hz
(kW)
0,25
SS025PSC
0,37
SS037PSC
0,55
SS055PSC
0,75
SS075PSC
1,10
SS110PSC
1,50
SS150PSC
2,20
SS220PSC
2
Type
Model
2
Number
284 623 3510
284 624 3510
284 625 3510
284 626 3510
284 627 3510
284 628 3510
284 629 3510
Current Ratings
Motor
Rating
(kW)
0,25
0,37
0,55
0,75
1,10
1,50
2,20
Specifications
Mechanical Specification
Protection level
Environment
External dimensions
Weight
Mounting
Storage temperature
Operation
temperature
Humidity
Electrical Specifications
Working Voltage
Rated insulation
voltage
1
Rated short-time
withstand current
Rated conditional
short-circuit current
Current
Power
Standards
IEC/EN 60439 - 1
Nom.
Max.
Current
Current
3
(A)
(A)
2,4
9,4
3,3
12,6
4,3
17,7
5,7
22,7
8,4
33,9
10,7
41,7
14,7
61,8
IP 54
This equipment is suitable
for environment B accor-
ding to IEC/EN 60439-1
195 x 168 x 85mm
0,6 - 1,0 kg
Wall mounting (mounting
hardware provided)
-25°C to +55°C
-5°C to +55°C
50% at 55°C (without con-
densation)
1~ / 50Hz
220 - 240V ±10%
400 Vac
1,5 kA
1 kA
16 A
0,25 - 2,2kW
Capacitor
4
450V (μF)
12,5
16
20
35
40
50
70
GB