Qlima PGP 113 Manuel D'utilisation page 6

Chauffage de patio à gaz
Masquer les pouces Voir aussi pour PGP 113:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
11. Connect the gas hose and regulator after that
10
12
connect the regulator to the gas cylinder.
WARNING! Ensure the hose does not contact
any high temperature surfaces, or it may melt
and leak causing a fire.
After the cylinder is placed inside the heater, secure
the cylinder with block belt tightly.
x 1
x 1
LL
x 1
KK
x 1
MM
12. Leak Check.
H
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually,and whenever any gas Components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing
Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections
of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Customer Care department and have the patio heater inspected by a certified gas installer.
14
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it,and have the patio heater inspected
by a certified gas installer or dealer. Do not use the patio heater until the leak has been corrected.
5 Regulador de manguera no
incluida.
3 Régulateur de gaz non
inclus.
4 Hose regulator not included.
> Tubo del gas non incluso.
u Slangeregulatoren følger
ikke med.
1 Slang van de gasregelaar
niet inbegrepen.
11
13
12
Hose / Regulator
connection
Regulator / Cylinder
connection
15
35

Publicité

Table des Matières
loading

Table des Matières