Setup
Pressure relief
Observe the pressure relief procedure if you see this symbol.
This equipment stays pressurized until pressure is manually relieved. To help
prevent serious injury from pressurized fluid, such as skin injection or splashed
fluid, follow the Pressure Relief Procedure whenever sprayer is stopped
and before sprayer is cleaned or checked, and before equipment is serviced.
1. Turn sprayer OFF.
2. Engage the trigger lock. Always engage the trigger lock when sprayer is stopped to
prevent the gun from being triggered accidentally.
3. Turn pressure control knob to lowest setting.
4. Put drain tube into a waste pail and turn Prime/Spray valve in PRIME position (drain)
to relieve pressure.
5. Hold the gun firmly to a pail. Point gun into pail. Disengage the trigger lock and trig-
ger the gun to relieve pressure.
6. Engage the trigger lock.
7. If you suspect the spray tip or hose is clogged or that pressure has not been fully relie-
ved:
a. VERY SLOWLY loosen the tip guard retaining nut or the hose end coupling to relieve
pressure gradually.
b. Loosen the nut or coupling completely.
c. Clear airless hose or spray tip obstruction. See Clear Tip Clog.