GB
NZ
2.9
Troubleshooting
Observe the safety instructions and maintenance instructions!
Problem
A
Rivet is not drawn in
completely
B
Rivet pin is difficult
to insert in the car-
rier piece or cannot
be inserted at all
(item 04)
C
Other causes
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
II/ 10
Cause
Carrier piece not compatible
with the rivet used (hole too
large).
Not enough oil in the oil piston
housing (item 05)
Incorrect claw housing setting
Claws damaged
Incorrect claw housing setting
Working pressure (flow pres-
sure) too low
Compressor output too small
Hose diameter too small
Remedy
Fit a carrier piece with the correct
***
hole size
Contact
Schneider
GmbH or an authorised service
****
partner.
See Chapter Commissioning "Ad-
justing the claw housing"
Contact Schneider Druckluft GmbH
or an authorised service part-
****
ner.
See Chapter Commissioning "Ad-
justing the claw housing"
Increase working pressure (flow
pressure)
Observe
working pressure
Use different output
*
rating
Use correct hose diameter
Druckluft
***
***
maximum
*
*