GB
RAS - SGS
2.9
Troubleshooting
Observe the safety instructions and maintenance instructions!
Problem
A
Screws
do
unscrew
B
Square bar does not
retain the socket
spanner
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
If necessary, contact our service staff, see last page.
II /10
Cause
not
Socket spanner worn
Air regulation adjusted
incorrectly
Working pressure (flow pres-
sure) too low
Compressor output too small
Hose diameter too small
Socket spanner worn
Retaining ring (item 06) /
Retaining ball (item 07) faulty
or missing
Square bar on the drive shaft
(item 03) worn
Remedy
Replace the socket spanner
Correct air
*
regulation
Increase working pressure (flow
pressure)
Observe
working pressure
Use different output
*
rating
Use correct hose diameter
Replace the socket spanner
Contact Schneider Airsystems or
your local service partner
Contact Schneider Airsystems or
your local service partner.
maximum
*
*