Maintenance; Troubleshooting Fault Codes - Vermeiren Venus 3 - 4 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
4

Maintenance

For the maintenance / cleaning instructions refer to the separate maintenance manual of the
scooters. Refer for these separate manual to your specialist dealer.
4.1

Troubleshooting Fault codes

The flashes on the battery indicator shows the fault codes. The number of
flashes (LED CODE) provides the information below (the following actions and
checks should only be carried out by authorised individuals). The LED CODE
exist out two numbers, the LED flashes in an interval of the first number,
followed by the interval of the second number. These sequence shall be
repeated until the fault is solved. (for example: LED CODE: 3,4 → 3 flashes
followed by 4 flashes).
LED CODE
PROBLEM / FAULT
1,1
Over- / under temperature
1,2
Throttle
1,3
Speed limit switch
1,4
Battery voltage too low
1,5
Battery voltage too high
2,1
Controller
2,3
Controller
2,4
Controller
3,1
Wiring
3,2
Magnetic brake goes not open
3,3
Magnetic brake
3,4
Magnetic brake in neutral
3,5
Throttle out neutral position
4,1
Current motor too high.
4,2
Current motor too low
4,3
Memory fault powermodule
4,5
Battery cables disconnected
SOLUTION
1. Cool down your scooter.
2. Remove excessive loads.
3. Do not drive in extreme environments.
Contact your dealer.
Contact your dealer.
1. Charge the battery
2. Check connections of battery or controller.
1. Replace battery.
2. Check that the charger is not attached to the
scooter.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Place neutral lever in drive.
1. Loosen the throttle.
2. Contact your dealer.
1. Switch scooter off and cool down the motor.
Contact your dealer.
Contact your dealer.
1. Check battery cables and connection points