- EN -
Translation of the original Operating Instructions
Information about these operating instructions
Welcome to OASE Living Water. Thank you for making a great decision and choosing our product Varionaut 270
DMX/02.
Prior to commissioning the unit, please read the instruction manual carefully and fully familiarise yourself with the unit.
Ensure that any work on or with this unit is carried out according to this manual.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place. Please also hand over the instructions when passing the unit on to a new
owner.
Symbols used in these instructions
GB
The symbols used in this operating manual have the following meanings:
Risk of injury to persons due to dangerous electrical voltage
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Risk of personal injury caused by a general source of danger
This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate
measures are not taken.
Important information for trouble-free operation.
A
Reference to a figure, e.g. Fig. A.
Reference to another section.
Product Description
A
Varionaut 270 DMX/02
1
Pump casing
The position of the outlet can be changed by fitting the pump casing rotated through 90°.
2
Outlet (pressure socket)
3
Inlet (suction socket)
4
Filter housing
5
Stand
Ensures secure and stable positioning of the pump.
Can be firmly bolted to the ground.
6
DMX line connection
Important: Moisture at the connections can damage the pump.
Only remove the protection caps for connecting the DMX lines.
Ensure that the rubber seals are clean and fit exactly.
Replace damaged rubber seals.
Varionaut 270 DMX/02 is a pump controlled via the DMX/RDM bus.
Water-tight plug-in cabling of the DMX/RDM bus via the DMX box. This makes it easier to connect the DMX controller
and other DMX-compatible consumers.
A DMX controller or DMX/RDM controller from OASE is used for controlling the unit.
– The DMX controller is not included in the scope of delivery. The application and extent of the system determine
the requirements for the DMX controller.
Intended use
Varionaut 270 DMX/02, referred to in the following as "unit", may only be used as specified in the following:
For pumping normal pond water for filters, waterfalls and water courses.
For use in fountain systems.
Operation under observance of the technical data.
Operation under observance of the recommended water quality.
- EN -
17